Author Archives: Webmaster

Safe Work Method Statement for Premix Plastering Work

Below is a detailed procedure for the installation of Premix Plaster, which is good to understand the way of work. Description of Activity: Surface Preparation The fair faced concrete background should be thoroughly cleaned  devoid of dust, loose particles, wood pieces, mould oil etc. The suction in the fair faced concrete back ground should be thoroughly… Read More: Safe Work Method Statement for Premix Plastering Work »

Safe Work Method Statement for Installation of Wall Padding Panels

Procedure and safe work method statement for installation of Wall padding panels. Below is only step wise procedure and complete method statement will have all sections like scope, references, responsibilities, ITP, Checklists and risk assessments. Description of Activity Preparation of the Sub construction: Lime/Cement plaster –The plaster must  adhere firmly to the sub construction and… Read More: Safe Work Method Statement for Installation of Wall Padding Panels »

Method Of Statement For Precommissioning & Commissioning of Chiller Plant Manager

PURPOSE : The purpose of this safe work method statement procedure is to define the step by step method to implement the correct practices for the precommissioning & commissioning of “Chiller Plant Manager or CPM”. Through the guidelines contained herein so as to ensure that the job execution complies with the project requirements and serves the intended function to… Read More: Method Of Statement For Precommissioning & Commissioning of Chiller Plant… »

Indoor Air Quality Environmental & Comfort Level Testing For HVAC System

The purpose of this procedure is to define the step by step method to implement the correct practices for the “Environmental Test including temperature and humidity levels” through the guidelines contained herein so as to ensure that the job execution complies with the project requirements and serves the intended function to satisfactory comfort level in the areas. TOOLS… Read More: Indoor Air Quality Environmental & Comfort Level Testing For HVAC… »

METHOD STATEMENT FOR PRECOMMISSIONING & COMMISSIONING OF EXTRACT FANS

The purpose of this procedure is to define the step by step method to implement the correct practices for the pre-commissioning & commissioning of Extract Fans through the guidelines contained herein so as to ensure that the job execution complies with the project requirements and serves the intended function to satisfactory level. Pre-commissioning Procedure for Extract Fans: Ensure… Read More: METHOD STATEMENT FOR PRECOMMISSIONING & COMMISSIONING OF EXTRACT FANS »

Method Statement For Installation of Glazing Panel to GRP Fins

Programs of work for the Installation of Glazing Panels to GRP Fin shall follow the Planning and Programming of the Main Contractor. In event of any major changes in execution or shift in milestones of work schedule could occur, revised method statement and work program shall be submitted for approval. Materials Submittal: Materials Submittal usually contains… Read More: Method Statement For Installation of Glazing Panel to GRP Fins »

Testing & Commissioning Of Fan Coil Units FCU’s

This method of statement is prepared in order to define the step by step method to implement the correct practices for the pre commissioning & commissioning of FCU’s Fan Coil Units through the guidelines contained herein so as to ensure that the job execution complies with the project requirements and serves the intended function to satisfactory level. REQUIRED… Read More: Testing & Commissioning Of Fan Coil Units FCU’s »